Transverse stiffeners and shear buckling: a 6 m beam in CalculiX
How transverse stiffener spacing affects elastic critical and ultimate shear resistance in a slender web, using linear buckling, nonlinear analysis with an initial imperfection, and a comparison with EN 1993-1-5.
Summary
We analysed the shear response of a 6 m I-beam with nonlinear shell elements, varying the spacing of the transverse stiffeners. Closer spacing raised both the elastic critical load and the ultimate shear resistance. The critical shear went from 446 kN with stiffeners only at the supports to 950 kN at 0.75 m spacing. The ultimate shear resistance rose from 1,279 kN at 3 m spacing to 1,740 kN at 0.75 m spacing, a 36% increase.
We also wanted to see what happens after buckling. The web deflects out of plane and develops a diagonal tension field that can carry further load. The values below are in kN. V is the shear in one half of the beam, equal to P/2, where P is the midspan force.
| Variant | Stiffener spacing | a/hw | Vcr [kN] | Vu [kN] | Vu/Vcr |
|---|---|---|---|---|---|
| V0 | Supports only (6 m) | 4.0 | 446 | 509 (*) | 1.14 |
| V1 | 3 m | 2.0 | 515 | 1,279 | 2.48 |
| V2 | 1.5 m | 1.0 | 627 | 1,586 | 2.53 |
| V3 | 1.0 m | 0.67 | 764 | 1,708 | 2.24 |
| V4 | 0.75 m | 0.5 | 950 | 1,740 | 1.83 |
In V0 the web fails locally beneath the concentrated load. Its 509 kN peak is excluded from the comparison of ultimate shear resistance.
The models were rerun with PrePoMax and CalculiX 2.22. The values agree with the earlier results from CalculiX 2.21.
Geometry and modelling
The S355 steel beam is 6 m long, with a 1,500 × 8 mm web, 400 × 20 mm flanges and paired 150 × 12 mm plate stiffeners. The load is applied at midspan. Every variant has stiffeners at the supports. Intermediate spacing varies from 6 m between the support stiffeners to 0.75 m.
The CalculiX model uses four-node shell elements (S4) with a 50 mm mesh. LISA was used for a linear static check. Its buckling elements and the node limit of the free version made it unsuitable for the nonlinear shell model used here.
- Linear buckling. The first eigenvalue λ gives the elastic critical shear Vcr = λ × 500 kN.
- Nonlinear analysis. The first buckling mode defines the initial web imperfection, scaled to min(a, hw)/200, between 3.75 and 7.5 mm depending on spacing. A prescribed midspan displacement then loads the beam. The steel is elastic–perfectly plastic with fy = 355 MPa, and the analysis includes large displacements to follow the post-peak response.
The support and load-point stiffeners are kept elastic. When those plates can yield, the peak stays near 1,070 kN across the spacings because the plate beneath the concentrated load fails first. Keeping the plates elastic lets us study the web response. The plates still require their own design checks.
The elastic critical shear rises with closer stiffeners
Shorter web panels increase the elastic critical stress. Vcr goes from 446 kN to 515 kN when a single intermediate stiffener is added at midspan, reaches 627 kN for four 1.5 m panels, and reaches 950 kN for eight 0.75 m panels. The last value is 2.13 times that of V0.
The PrePoMax images show the first buckling mode. The colour scale represents normalised out-of-plane web displacement in millimetres.

V0, support stiffeners only. λ₁ = 0.892 and Vcr = 446 kN.

V1, 3 m spacing. λ₁ = 1.03 and Vcr = 515 kN.

V2, 1.5 m spacing. λ₁ = 1.254 and Vcr = 627 kN.

V4, 0.75 m spacing. λ₁ = 1.899 and Vcr = 950 kN.
The expression for a single panel simply supported on all four edges gives 605 kN for V2, within 4% of the model’s 627 kN. The model gives a higher value for V1 (515 versus 411 kN) and lower values for V3 (764 versus 1,037 kN) and V4 (950 versus 1,643 kN). The whole-beam model includes bending and the concentrated load, effects omitted in the single-panel expression. Their influence at close spacing remains to be checked separately.
Beyond buckling: diagonal tension field action
After buckling, the diagonal compression changes little. Diagonal tension continues to increase and anchors into the flanges and stiffeners, so the peak load is well above the elastic critical load. For V1 to V4 the peak ranges from 1.8 to 2.5 times Vcr. The ratio rises from 2.48 in V1 to 2.53 in V2, then falls to 2.24 in V3 and 1.83 in V4.
The load–displacement curves show the initial response, loss of stiffness, peak and descending branch. The horizontal axis uses the displacement prescribed at the midspan load reference. The peaks occur at about 14 mm for V1, 17 mm for V2, and 22 mm for V3 and V4. The V2 video uses the vertical displacement of midspan node 1876 instead, which is 15.2 mm at the same increment. Both give a peak of about 1,586 kN.

Shear–displacement curves from CalculiX. The dotted line marks the plastic shear resistance.
The maps show equivalent plastic strain (PEEQ) at the final increment, after peak load. PrePoMax uses an automatic colour scale for each image.

V1, 3 m spacing. The diagonal tension field spans the slender panel. Maximum PEEQ is 5.5%.

V2, 1.5 m spacing. The tension field is distributed across several panels. Maximum PEEQ is 6.5%.

V4, 0.75 m spacing. The closely spaced stiffeners limit the spread of the tension field. Maximum PEEQ is 5.1%.
The deformed shape also changes. In V1 the web deflects along a diagonal.

V1, final displacement. PrePoMax amplifies the deformed geometry.
In V4 the displacement concentrates beneath the load, with local downward movement and a fold in the web.

V4, final displacement.
The V0 web fails locally beneath the concentrated load before a fully developed tension field can form. The nonlinear solution stops converging shortly after the 509 kN peak.
Ultimate shear resistance and the Eurocode comparison
Relative to V1 at 3 m spacing, the ultimate resistance rises by 24% in V2, 34% in V3 and 36% in V4. From V3 to V4 it rises by only 2%, even though the elastic critical shear rises by another 24%. Web yielding becomes the limiting mechanism. The plastic shear resistance is Vpl = hw × tw × fy / √3 = 2,459 kN. V4 reaches 71% of that value.
We compared the results with the EN 1993-1-5:2006 method for non-rigid and rigid end posts. The comparison uses the 2006 edition.
| Variant | FEM Vu [kN] | EN, non-rigid [kN] | EN, rigid [kN] | FEM / rigid EN |
|---|---|---|---|---|
| V1 (3 m) | 1,279 | 899 | 1,131 | 1.13 |
| V2 (1.5 m) | 1,586 | 1,108 | 1,316 | 1.20 |
| V3 (1.0 m) | 1,708 | 1,400 | 1,547 | 1.10 |
| V4 (0.75 m) | 1,740 | 1,669 | 1,752 | 0.99 |
Both methods show increasing resistance as the spacing decreases. For V1 to V3 the FEM result is 10–20% above the rigid-end-post estimate. The two estimates are nearly equal for V4. The equations still need checking against the standard before the comparison is used in a design report.
Study limitations
- Elastic stiffeners. The support and load-point stiffeners stay elastic in the model. The slender 150 × 12 mm plates require their own resistance and stability checks. Allowing those plates to yield caps the resistance at around 1,070 kN across the spacings.
- Mesh. Changing the V2 mesh from 50 mm to 25 mm lowers Vu by 4.2%. The coarser mesh therefore gives a higher resistance in this check.
- Imperfections. The model uses one imperfection shape and amplitude, without residual stresses. Real imperfections and residual stresses could lower resistance.
- V0 failure mode. The concentrated load governs V0. Its elastic critical shear can be compared with the other variants, while its peak resistance reflects local loading.
- Eurocode calculations. The comparison uses the 2006 formulas, which require checking against the standard before use in a report.
- Images. The PrePoMax figures show the first buckling mode or the last converged nonlinear increment. They do not show the beam at peak load.
Conclusions
Transverse stiffeners raise both the elastic critical shear and the ultimate shear resistance. Adding stiffeners every 0.75 m raises the elastic critical shear from 446 to 950 kN relative to stiffeners at the supports only. Ultimate resistance rises from 1,279 to 1,740 kN between 3 m and 0.75 m spacing, with most of the gain achieved at 1 m spacing.
After buckling, the diagonal tension field carries further load and the peak reaches 1.8–2.5 times the elastic critical shear. The plastic strain plots show an extensive band in slender panels and a more localised response near the load in shorter panels.
The next steps are to design the support and load-point stiffeners and check the Eurocode comparison against the text of the standard.